Technical Data
****************
Core identification code :
DIN 47100 without colour repetition, see Appendix
T9
Mutual capacitance:
C/C approx. 120 nF/km C/S: approx. 160 nF/km
Peak working voltage:
(not for power applications) 250 V
Inductivity :
approx. 0.65 mH/km
Based on:
VDE 0812
Specific insulation resistance:
> 20 GOhm x cm
Conductor stranding:
Strand, fine wire 0.34 mm², 7 wire
Conductor resistance:
see Appendix T11
Minimum bending radius:
For flexible applications: 15 x outer diameter fixed
installation: 6 x cable diameter
Test voltage:
At 0.14 mm2: 1200 V
> 0.14 mm2: 1500 V
Range of temperature:
Fixed installation: -40°C up to +80°C
Flexing: -5°C up to +70°C
********